The American Standard YHC033A is a high-efficiency residential gas furnace, part of the AccuComfort™ Platinum Series. It features variable-speed blower technology, two-stage gas valve operation, durable aluminized steel heat exchanger, integrated communicating control system, compatibility with zoning systems, quiet operation, and high AFUE ratings. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Variable-speed ECM blower motor, Two-stage gas valve, Aluminized steel primary heat exchanger, Stainless steel secondary heat exchanger, Integrated control board, Pressure switch, Flame sensor, Ignition control module.
| Feature | Description |
|---|---|
| Variable-Speed Blower | Provides precise airflow control for comfort and efficiency |
| Two-Stage Gas Valve | Operates at low fire for mild days, high fire for extreme cold |
| AccuComfort™ Control | Communicating system for optimal performance with matching thermostats |
| Aluminized Steel Heat Exchanger | Durable construction for long service life |
| Quiet Operation | Insulated cabinet and variable-speed motor reduce noise |
| Zoning Compatible | Works with American Standard zoning systems for room-by-room control |
| Diagnostic LED | Flashing code indicator for troubleshooting |
| Filter Rack | Standard 1" or optional 4" media filter compatibility |
| Vent Connections | PVC pipe compatible for direct vent installation |
| Safety Controls | Includes rollout switches, pressure switch, and high-limit controls |
Unpack and inspect contents. Ensure proper location with adequate clearance.
WARNING! Installation must comply with all local codes and be performed by qualified personnel. Gas leaks can cause explosion or fire.
Power on furnace; follow startup procedure.
CAUTION! Never bypass safety controls. Ensure proper ventilation to prevent carbon monoxide buildup.
Access settings via thermostat or control board dip switches. Control Board: LED diagnostic light, DIP switches for configuration, terminal strip for connections.
Thermostat Settings: SYSTEM (Heat/Cool/Off), FAN (Auto/On), Temperature setpoint, Schedule programming, Zoning configuration, Filter reminder reset.
DIP Switch Settings: Heating stages (1 or 2), Blower off delay, Cooling speed, Heat speed, Accessory configuration. Diagnostic Codes: LED flash patterns indicate specific faults (1 flash = pressure switch, 2 flashes = ignition failure, etc.).
Use AccuLink communicating thermostat for full functionality. Conventional thermostats can be used with adapter module.
Tip: Use 18-gauge thermostat wire. Keep low-voltage wires separated from line voltage.
Two-stage heating with variable airflow.
WARNING! Do not operate furnace without filter. Restricted airflow can damage heat exchanger.
Monthly: Check filter, clean if reusable. Annually: Professional inspection and cleaning.
Professional maintenance should include: Heat exchanger inspection, Burner cleaning, Flame sensor cleaning, Blower cleaning and lubrication check, Vent system inspection, Gas pressure verification, Safety control testing, Carbon monoxide check.
Turn off power and gas before servicing. Use soft brush and vacuum for cleaning.
CAUTION! Never use water or chemical cleaners on electrical components. Keep area around furnace clear of combustible materials.
UL listed and ANSI Z21.47 certified. Complies with U.S. Department of Energy efficiency standards. Manufactured to meet or exceed ASHRAE 90.1 requirements. For support, visit www.americanstandardair.com or contact 1-800-628-4516. Copyright © American Standard Heating & Air Conditioning.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Furnace won't start | Power, thermostat, switch | Check circuit breaker, thermostat setting, door switch, gas valve. |
| Blower runs continuously | Thermostat fan setting | Set thermostat fan to AUTO; check fan relay. |
| No heat | Ignition failure | Check gas supply, pressure switch, flame sensor, igniter. |
| Short cycling | Filter, airflow, limit | Replace filter; check for blocked vents; test limit switch. |
| Unusual noises | Blower, ductwork | Check for loose parts, debris in blower, duct restrictions. |
| Error code flashing | System fault | Count LED flashes and refer to fault code chart in manual. |
Reset: Turn power off for 30 seconds, then restore. If fault persists, call for service.
Service: 1-800-628-4516; www.americanstandardair.com