The American Standard YCC030F-L is a high-efficiency residential condensing unit designed for reliable cooling performance. This 2.5-ton unit features a scroll compressor, corrosion-resistant coil, and operates with R-410A refrigerant. It is compatible with American Standard matched indoor units for optimized system performance. Below are key sections covering safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Scroll compressor, louvered coil guard, weather-resistant cabinet, service valves, electrical disconnect.
| Feature | Description |
|---|---|
| Compressor Type | High-efficiency scroll compressor |
| Refrigerant | R-410A |
| Coil Construction | Corrosion-resistant copper tube/aluminum fin |
| Cabinet | Galvanized steel with powder coat finish |
| Sound Level | Reduced operational noise design |
| Electrical Requirements | 208/230V, 1-phase, 60Hz |
| Cooling Capacity | 30,000 BTU/h (2.5 tons) |
| SEER Rating | Up to 16 SEER (with matched indoor unit) |
| Connections | Liquid and suction service valves |
| Warranty | Limited 10-year compressor warranty |
Unpack and inspect for shipping damage. Select a suitable outdoor location.
WARNING! Installation must be performed by a qualified HVAC technician. Incorrect installation can cause injury or equipment failure.
After installation, perform system commissioning.
CAUTION! Do not operate without proper refrigerant charge. Allow 24 hours for refrigerant to stabilize after installation.
Primary control is via a compatible thermostat. Unit has internal protection controls.
Thermostat Operation: Set to COOL, AUTO fan, desired temperature. System cycles automatically.
Unit Controls: Internal high/low pressure switches, compressor overload protector, anti-short cycle timer.
LED Status Light: Located on control board. Steady = normal operation. Flashing = fault condition (refer to code chart).
Refer to wiring diagram on unit service panel.
Tip: Use copper conductors only. Torque electrical connections to specifications on diagram.
Annual maintenance by a qualified technician is recommended.
WARNING! Turn off power at disconnect before performing any maintenance. Do not attempt to service refrigerant system.
High-Pressure Switch: Shuts off compressor if discharge pressure is excessive. Low-Pressure Switch: Protects compressor from low refrigerant charge. Compressor Overload: Internal thermal protection. Anti-Short Cycle Timer: Prevents rapid compressor cycling (minimum 5-minute off time).
Keep the outdoor unit clear of vegetation, leaves, and snow. Clean the coil surface annually with a garden hose (spray from the inside out). Do not use pressure washers.
CAUTION! Do not bend or damage the aluminum fins. Keep the top discharge area unobstructed.
This unit complies with applicable UL and CSA standards. It contains refrigerant that must be recovered by an EPA-certified technician. Manufactured by American Standard Heating & Air Conditioning. For technical support or warranty service, contact your local American Standard dealer or visit www.americanstandardair.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit does not start | Power loss, thermostat setting, tripped breaker | Check disconnect and breaker. Verify thermostat is in COOL mode below room temp. |
| Unit runs but does not cool | Dirty filter, low refrigerant, dirty coil | Replace indoor filter. Clean outdoor coil. Call technician for charge check. |
| Unit cycles on/off rapidly | Dirty filter, restricted airflow, overcharge | Replace filter. Check for blocked registers or ductwork. Call technician. |
| Ice on refrigerant lines | Low airflow, low refrigerant | Replace filter. Check for blocked indoor coil. Call technician. |
| Unusual noise | Loose parts, debris in fan, failing motor | Turn off power. Tighten cabinet panels. Remove debris. Call for service if noise persists. |
| LED flashing code | Fault condition (pressure, sensor, etc.) | Note flash pattern and consult service manual. Call qualified technician. |
Reset: Turn thermostat to OFF. Turn off power at disconnect for 5 minutes. Restore power and thermostat.
Service: Contact your local American Standard dealer. For product information: www.americanstandardair.com