American Standard HVAC TWE024C14 Manual

The American Standard TWE024C14 is a high-efficiency, two-stage heat pump system designed for residential use. It features advanced humidity control, quiet operation, compatibility with variable-speed air handlers, and meets ENERGY STAR® requirements. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Thermostat 7. Operation Modes 8. Maintenance Schedule 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Outdoor heat pump unit, indoor air handler/coil, thermostat, refrigerant lines, electrical connections.

FeatureDescription
Two-Stage OperationProvides efficient heating and cooling with two capacity levels
High SEER RatingUp to 18 SEER for energy savings
Quiet OperationSound-dampening compressor and fan design
Humidity ControlEnhanced dehumidification in cooling mode
Compatible ThermostatsWorks with American Standard communicating and conventional thermostats
Durable ConstructionWeather-resistant cabinet with corrosion protection
RefrigerantUses R-410A environmentally friendly refrigerant
Service PortsEasy-access ports for pressure checking and charging
Safety SwitchesHigh and low-pressure switches, compressor overload protection
Diagnostic LEDFlashing LED for troubleshooting codes

Installation

Unpack and inspect contents. Place outdoor unit on level pad.

  1. Position outdoor unit: Install on concrete pad or approved mounting system with proper clearances.
  2. Connect refrigerant lines: Braze copper lines between indoor and outdoor units following EPA guidelines.
  3. Connect electrical: Run high-voltage power to disconnect box; connect low-voltage thermostat wires.
  4. Connect condensate drain: Ensure proper drainage from indoor unit to prevent water damage.
  5. Vacuum and charge system: Evacuate to 500 microns; charge with correct amount of R-410A.

WARNING! Installation must be performed by qualified HVAC technician. Refrigerant handling requires EPA certification.

First-Time Setup

Power on system; configure thermostat settings.

  1. System power-up: Turn on power at disconnect and indoor unit; wait for system initialization.
  2. Thermostat configuration: Set system type to heat pump, configure staging, fan operation.
  3. Test operation: Run system in cooling and heating modes to verify proper function.
  4. Check airflow: Verify adequate airflow at all supply registers.
  5. Monitor pressures: Confirm operating pressures are within manufacturer specifications.

CAUTION! Do not operate without proper refrigerant charge. Ensure electrical connections are tight.

Specifications

Controls and Settings

Access system settings via compatible thermostat. Outdoor unit has diagnostic LED.

Thermostat Settings: SYSTEM (Off, Heat, Cool, Auto, Emer Heat), FAN (Auto, On), TEMPERATURE setpoints, STAGING configuration, HUMIDITY control, SCHEDULE programming.

Advanced Settings: Compressor lockout temperatures, fan delay, filter reminder, diagnostic mode. Outdoor Unit: Service valve positions, diagnostic LED codes (1 flash = normal, 2 flashes = low pressure, 3 flashes = high pressure, etc.).

Connecting Thermostat

Use 18-gauge thermostat wire with at least 5 conductors (R, C, Y1, Y2, O/B, G, W1, W2).

  1. Turn off power to indoor and outdoor units at disconnect boxes.
  2. Remove thermostat cover and connect wires to appropriate terminals.
  3. Match colors: R (24V power), C (common), Y1 (cool stage 1), Y2 (cool stage 2), O/B (reversing valve), G (fan), W1 (heat stage 1), W2 (heat stage 2).
  4. Configure thermostat for heat pump operation with auxiliary/emergency heat.
  5. Restore power and test all functions.

Tip: Label wires before disconnecting old thermostat. Use wire nuts for secure connections.

Operation Modes

System operates in multiple modes for comfort and efficiency.

  1. Cooling Mode: Compressor runs in stage 1 or 2 based on cooling demand.
  2. Heating Mode: Heat pump extracts heat from outdoor air; reverses refrigerant flow.
  3. Emergency Heat: Uses backup electric heat strips when heat pump cannot meet demand.
  4. Auto Mode: Automatically switches between heating and cooling based on room temperature.
  5. Fan Only: Circulates air without heating or cooling.
  6. Dehumidify: Enhances moisture removal in cooling mode.

WARNING! Do not switch between heating and cooling modes rapidly. Allow 5-minute delay between mode changes.

Maintenance Schedule

Regular maintenance ensures optimal performance and longevity.

FrequencyTask
MonthlyCheck/change air filter
SeasonallyClean outdoor coil, clear debris around unit
AnnuallyProfessional inspection: check refrigerant charge, electrical connections, drain lines, coil cleanliness
Every 3-5 yearsProfessional deep cleaning of indoor coil and blower assembly

Care & Cleaning

Turn off power before cleaning. Keep outdoor unit clear of debris.

  1. Outdoor unit: Remove leaves, grass clippings; clean coil with gentle water spray (not pressure washer).
  2. Indoor unit: Clean evaporator coil accessibly; ensure drain pan and line are clear.
  3. Air filter: Replace disposable filters or clean permanent filters monthly during peak use.
  4. Condensate drain: Pour 1 cup vinegar through drain line annually to prevent algae growth.

CAUTION! Do not bend coil fins. Keep electrical components dry during cleaning.

Regulatory Information

UL listed; meets ASHRAE standards. EPA Section 608: Contains refrigerant; service must be performed by certified technician. ENERGY STAR® qualified. California Proposition 65 warning: This product may contain chemicals known to cause cancer or reproductive harm. For support, visit www.americanstandard.com or contact 1-800-628-4516.

Troubleshooting

SymptomPossible CauseCorrective Action
System not turning onPower loss, tripped breaker, thermostat issueCheck disconnect switches and circuit breakers; verify thermostat settings and batteries.
Insufficient cooling/heatingDirty filter, low refrigerant, blocked airflowChange filter; clear obstructions; call technician for refrigerant check.
Outdoor unit not runningLockout mode, faulty capacitor, sensor issueCheck diagnostic LED; reset power; call technician.
Ice on outdoor coilLow refrigerant, dirty coil, low airflowTurn system off to defrost; clean coil; call technician.
Water leakage indoorsClogged drain line, disconnected drainClear drain line; ensure proper slope; check drain pan.
Unusual noisesLoose parts, failing motor, debris in fanTurn off system; inspect for obstructions; call technician.

Reset: Turn off power at disconnect for 5 minutes, then restore.

Service: 1-800-628-4516; www.americanstandard.com