American Standard HVAC TVF024A14 Manual
The American Standard TVF024A14 is a high-efficiency variable-speed air handler designed for use with compatible heat pumps and air conditioners. It features a multi-speed ECM blower motor, durable cabinet construction, compatibility with R-410A refrigerant systems, and integrated control board for seamless system operation. Below are key sections covering safety, specifications, installation, wiring, operation, maintenance, and troubleshooting.
Features at a Glance
Key components: Galvanized steel cabinet, ECM variable-speed blower motor, integrated control board, filter rack, drain pan, and service access panels.
| Feature | Description |
| Blower Motor | Electronically Commutated Motor (ECM) for variable-speed operation and energy efficiency |
| Cabinet Construction | Galvanized steel with baked enamel finish for corrosion resistance |
| Control Board | Integrated board for system communication and blower control |
| Filter Rack | Standard 1-inch or optional 2-inch media filter compatibility |
| Drain Pan | Molded plastic with primary and secondary drain connections |
| Refrigerant Compatibility | Designed for R-410A systems |
| Voltage Rating | 208/230V, 1-phase, 60 Hz |
| Airflow Range | Adjustable from 600 to 1200 CFM |
| Sound Insulation | Internal insulation for reduced operational noise |
| Service Access | Removable panels for easy maintenance |
Installation Requirements
Unpack and inspect unit for shipping damage. Install on level surface in indoor location.
- Location: Install in conditioned space such as basement, utility room, or attic (if properly insulated). Ensure minimum clearances: 24 inches front, 6 inches sides/rear, and adequate overhead for service.
- Mounting: For horizontal installation, use sturdy hanging rails or platform. For vertical upflow installation, ensure stable base platform.
- Ductwork Connection: Connect supply and return ducts securely using approved methods. Seal all joints with mastic or UL-181 approved tape.
- Condensate Drain: Connect primary drain line to drain pan outlet. Install secondary safety drain line per local codes. Ensure proper slope (1/4 inch per foot minimum).
- Electrical Power: Disconnect all power before making connections. Provide dedicated circuit per specifications.
WARNING! Unit is heavy; use proper lifting equipment and multiple personnel. Ensure installation complies with all local codes and ordinances.
Wiring & Electrical Connections
All wiring must be performed by qualified personnel in accordance with NEC and local codes.
- Power Supply: Connect 208/230V, 1-phase power to unit disconnect. Use copper conductors only. Size wires per unit nameplate and NEC requirements.
- Low-Voltage Wiring: Connect thermostat wires to control board terminals (R, C, Y1, Y2, G, O/B, etc.). Use 18 AWG shielded cable for runs over 50 feet.
- Grounding: Connect equipment grounding conductor to ground lug in control box.
- System Communication: For communicating systems, connect proprietary communication wires between air handler and outdoor unit as specified in system manual.
- Field-Supplied Disconnect: Install a fused disconnect or circuit breaker within sight of unit per NEC requirements.
CAUTION! Verify power is OFF with voltmeter before servicing. Incorrect wiring can cause equipment damage, fire, or personal injury.
Specifications
- Model: TVF024A14
- Nominal Cooling Capacity: 2 Tons (24,000 BTU/h)
- Airflow Range: 600-1200 CFM (adjustable)
- External Static Pressure: Up to 0.8 inches w.c.
- Motor Type: ECM variable-speed
- Motor HP: 1/3 HP
- Voltage: 208/230V, 1-Phase, 60 Hz
- Min/Max Circuit Ampacity: 15.2 / 12.1 A
- Min/Max Overcurrent Protection: 25 A
- Control Voltage: 24V AC
- Refrigerant Connections: 3/4" liquid line, 7/8" suction line (sweat connections)
- Cabinet Dimensions (HxWxD): 44" x 17.5" x 21"
- Shipping Weight: 98 lbs
- Operating Ambient Temperature: 45°F to 120°F
Control Board & Settings
Access control board by removing service panel. Board includes LED status indicators, DIP switches, and terminal connections.
DIP Switch Settings: Configure for system type (heat pump/conventional), blower speeds, and accessory options.
LED Indicators: Green (power), Yellow (communication), Red (fault). Blink patterns indicate specific status or error codes.
Terminal Connections: Standard terminals for thermostat (R, C, Y1, Y2, G, O/B, W1, W2, etc.) and outdoor unit connections.
Blower Speed Settings: Adjust cooling, heating, and continuous fan speeds via DIP switches or jumper settings per installation requirements.
Factory Default: DIP switches set for standard 2-ton heat pump application. Adjust per specific system requirements.
Startup & Commissioning
Complete after installation and wiring verification.
- Pre-Start Check: Verify all electrical connections are tight. Ensure filter is installed. Confirm drain lines are clear and properly trapped.
- Power On: Restore power at disconnect. Green LED on control board should illuminate steady.
- System Check: Set thermostat to COOL mode, temperature below room temp. Verify outdoor unit and blower activate. Check airflow at registers.
- Airflow Measurement: Measure external static pressure and adjust blower speed if necessary to achieve design airflow.
- Heating Mode Test: Set thermostat to HEAT mode, temperature above room temp. Verify proper operation in heating mode.
- Safety Controls Test: Verify high-limit control, condensate overflow switch, and other safety devices function properly.
Tip: Use manufacturer's commissioning report to document all measurements and settings.
Operating Instructions
For normal homeowner operation via thermostat.
- Thermostat Settings: Use compatible thermostat to select mode (COOL, HEAT, OFF, FAN AUTO/ON). Set desired temperature.
- Continuous Fan Operation: Set thermostat fan to ON for continuous circulation. System will operate blower at low speed when not heating or cooling.
- System Response: When thermostat calls for cooling or heating, blower will ramp up to appropriate speed. ECM motor provides smooth, quiet operation.
- Dehumidification: In cooling mode, variable-speed operation enhances dehumidification by running at lower speeds for longer periods.
- System Shutdown: Set thermostat to OFF position. Blower will complete post-purge cycle if programmed.
WARNING! Do not adjust DIP switches or control board settings without proper training. Incorrect settings can reduce efficiency or damage equipment.
Maintenance Procedures
Regular maintenance ensures optimal performance and longevity.
- Monthly: Check and replace air filter as needed. Restricted filters reduce airflow and efficiency.
- Seasonal: Inspect drain pan and condensate lines. Clean if necessary to prevent algae growth and blockage.
- Annual (Professional): Have qualified technician inspect blower assembly, clean evaporator coil if accessible, check electrical connections, verify system operation, and measure performance.
- Blower Maintenance: Every 3-5 years, have technician clean blower wheel and housing. Check motor bearings and lubricate if required (some ECM motors are permanently lubricated).
- Cabinet Inspection: Check for rust, corrosion, or damage. Ensure all access panels are secure.
CAUTION! Disconnect all power before performing any maintenance. Do not attempt to service electrical components without proper qualification.
Safety Information
Important safety precautions for installation, operation, and maintenance.
- Electrical Safety: Always disconnect power at service disconnect before working on unit. Use lockout/tagout procedures.
- Fire Safety: Keep unit clear of combustible materials. Maintain required clearances.
- Personal Safety: Unit contains sharp edges. Wear gloves and eye protection during service.
- Refrigerant Safety: Only EPA-certified technicians should service refrigerant circuit. System contains R-410A under high pressure.
- Lifting Safety: Unit is heavy. Use proper lifting techniques and equipment.
- Carbon Monoxide: If used with gas/electric furnace section, ensure proper venting and install CO detectors in living spaces.
Regulatory Compliance
This equipment complies with applicable standards and regulations.
- UL Certification: Listed under UL 1995
- Energy Compliance: Meets U.S. DOE energy efficiency standards
- Refrigerant: Complies with EPA Section 608 regulations for R-410A systems
- Electrical: Designed per NEC Article 440 and NFPA 70 requirements
- Warranty: Limited warranty coverage; refer to warranty certificate for details. Registration required within 60 days of installation.
- Manufacturer: American Standard Heating & Air Conditioning. For technical support, contact 1-800-628-4516 or visit www.americanstandardair.com
Troubleshooting Guide
| Symptom | Possible Cause | Corrective Action |
| Unit not operating | Power loss, tripped breaker, thermostat issue | Check disconnect and circuit breaker. Verify thermostat settings and batteries. Check for 24V at control board. |
| Blower not running | Control board fault, motor failure, airflow switch | Check control board LEDs. Verify motor receives voltage. Check for blocked filter or restricted ductwork. |
| Insufficient airflow | Dirty filter, closed dampers, incorrect speed setting | Replace filter. Check duct dampers. Verify blower speed settings match duct design. |
| Water leakage | Clogged drain line, improper slope, cracked pan | Clear drain line. Ensure proper slope (1/4" per foot). Inspect drain pan for cracks. |
| Unusual noise | Loose components, debris in blower, motor bearing | Tighten all panels and hardware. Inspect blower wheel for debris. Listen for bearing noise. |
| Frequent cycling | Dirty filter, thermostat location, oversized unit | Clean/replace filter. Ensure thermostat not in direct sunlight or draft. Verify proper system sizing. |
| Error code on control board | System fault detected | Refer to service manual for specific error code diagnosis. Common codes: communication failure, motor fault, sensor error. |
Reset Procedure: Power unit off at disconnect for 60 seconds, then restore power. If problem persists, contact qualified technician.
Service Support: For technical assistance, contact American Standard at 1-800-628-4516. Have model and serial numbers ready.