American Standard HVAC CUBA24A4ACC Manual

The American Standard CUBA24A4ACC is a high-efficiency, single-stage, 2-ton air conditioning condensing unit designed for residential use. It features a durable WeatherGuard™ cabinet, Spine Fin™ coil technology for enhanced heat transfer, low sound operation, and compatibility with American Standard matched indoor units for optimal performance. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Components 7. Operation 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: WeatherGuard™ cabinet, Spine Fin™ coil, single-speed scroll compressor, low-pressure switch, high-pressure switch, fan motor, and refrigerant connections.

FeatureDescription
WeatherGuard™ CabinetDurable, corrosion-resistant painted steel with louvered panels
Spine Fin™ CoilEnhanced heat transfer and corrosion resistance
Scroll CompressorSingle-stage, reliable operation with low sound levels
Low/High Pressure SwitchesProtects system from refrigerant pressure faults
Fan MotorPermanent split capacitor (PSC) type for efficient airflow
Refrigerant Connections¼" SAE flare liquid and suction service ports
Electrical ConnectionWeatherproof quick-connect terminals
Sound InsulationInternal sound-dampening features for quiet operation
Factory ChargeR-410A refrigerant for matched indoor units up to 25 ft lineset
CompatibilityDesigned for use with American Standard matched air handlers/furnaces

Installation

Unpack and inspect contents. Place on stable, level pad.

  1. Select Location: Ensure adequate clearance (24" minimum on all sides, 48" above).
  2. Place Pad: Use concrete or composite pad; level unit.
  3. Connect Refrigerant Lines: Braze lineset to unit connections using nitrogen purge.
  4. Connect Electrical: Run 240V power from disconnect to unit terminals (L1, L2, Ground).
  5. Connect Control Wiring: Run 24V control wires from indoor unit to thermostat terminals.
  6. Evacuate and Charge: Evacuate system to 500 microns, charge per nameplate/subcooling.

WARNING! Installation must be performed by a qualified HVAC technician. Follow all local codes and safety procedures.

First-Time Setup

After installation, perform initial startup and system check.

  1. Verify Installation: Check all electrical and refrigerant connections are tight.
  2. Set Thermostat: Install compatible thermostat; set to OFF mode.
  3. Power On: Turn on power at disconnect and indoor unit.
  4. Start System: Set thermostat to COOL, temperature below room temp.
  5. Check Operation: Verify compressor and fan start; listen for unusual noises.
  6. Measure Performance: Check superheat/subcooling; measure temperature drop across indoor coil.

CAUTION! Do not operate without proper refrigerant charge. Ensure electrical power is off during wiring.

Specifications

Controls and Settings

Primary control via thermostat. Unit includes internal protection controls.

Thermostat Settings: COOL, OFF, FAN (ON/AUTO). Set desired temperature.

Unit Controls: Internal high/low pressure switches, compressor thermal overload, fan delay on shutdown.

Dip Switches (if applicable on indoor unit): May adjust fan delay, airflow, or staging.

No user-serviceable controls on outdoor unit. All adjustments require qualified technician.

Connecting Components

Connect to matched indoor unit (air handler or furnace) and thermostat.

  1. Turn off all power at disconnect and indoor unit.
  2. Connect Refrigerant Lines: Liquid (small) and suction (large) lines to corresponding ports.
  3. Connect Power: 240V lines to L1, L2, and ground terminal.
  4. Connect Control: 24V lines from indoor unit (Y, C, possibly O/B) to outdoor unit terminal block.
  5. Restore power in sequence: indoor unit first, then outdoor disconnect.

Tip: Label all wires before disconnecting. Use copper conductors only.

Operation

Normal cooling operation via thermostat.

  1. Set thermostat to COOL mode and desired temperature.
  2. Fan setting: AUTO (runs with compressor) or ON (continuous).
  3. Compressor and outdoor fan will cycle on to meet set temperature.
  4. In OFF mode, system does not cool. Fan may run if set to ON.
  5. Unit may have a short time delay between cycles (approx 5 minutes).

WARNING! Do not cover or block airflow to unit. Keep area clear of debris.

Maintenance

Regular maintenance ensures efficiency and longevity.

CAUTION! Turn off power before any cleaning or inspection. Do not use pressure washer.

Care & Cleaning

Keep unit clean for optimal performance.

  1. Turn off power at disconnect.
  2. Remove leaves, grass clippings, and debris from top and sides.
  3. Gently rinse coil with garden hose (nozzle setting: shower). Spray from inside facing out to push debris outwards.
  4. Straighten any bent coil fins with a fin comb.
  5. Ensure drain ports at base are clear.

CAUTION! Do not use chemicals, solvents, or steam cleaners. Do not bend fins excessively.

Regulatory Information

This product complies with applicable DOE energy efficiency standards and UL safety standards. Refrigerant handling must comply with EPA Section 608 regulations. Manufactured by American Standard Heating & Air Conditioning, a division of Trane Technologies. For support, contact your local American Standard dealer or visit www.americanstandardair.com.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower off, tripped breaker, thermostat settingCheck disconnect and breaker; verify thermostat is in COOL mode below room temp.
Fan runs, compressor does notLow/high pressure lockout, time delay, faulty capacitorWait 5 mins; if no start, call technician to check pressure, capacitor, contactor.
Reduced coolingDirty filter/coil, low refrigerant, restricted airflowReplace indoor filter; clean outdoor coil; call technician to check charge.
Unit cycles on/off rapidlyDirty coil, overcharge, faulty sensorClean coil; call technician to check charge and sensors.
Ice on refrigerant lines or coilLow airflow, low refrigerant chargeTurn system off; check/replace indoor filter; call technician when thawed.
Unusual noiseDebris in fan, loose parts, failing motorTurn off power; remove debris; tighten access panels; call technician if noise persists.

Reset: Turn thermostat OFF, turn off power at disconnect for 30 seconds, then restore.

Service: Contact a qualified American Standard dealer. Do not attempt internal repairs.