American Standard HVAC 5A7A5036A Manual

The American Standard 5A7A5036A is a high-efficiency residential air conditioning unit designed for reliable cooling performance. This manual covers safety guidelines, installation procedures, operation instructions, maintenance schedules, and troubleshooting for the 5A7A5036A model. Below are key sections for features, installation, setup, specifications, controls, wiring, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation Requirements 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Electrical Wiring 7. Operation Instructions 8. Maintenance Schedule 9. Safety Information 10. Warranty Information 11. Troubleshooting

Features at a Glance

Key components: High-efficiency scroll compressor, aluminum coil, weather-resistant cabinet, low-sound operation, factory-installed filter drier, and liquid line solenoid valve.

FeatureDescription
Compressor TypeScroll compressor for quiet, efficient operation
Coil MaterialAluminum for corrosion resistance
RefrigerantR-410A, environmentally friendly
Sound LevelLow outdoor sound rating
CabinetGalvanized steel with powder coat paint
Electrical Requirements208/230V, 1 phase, 60 Hz
SEER RatingHigh Seasonal Energy Efficiency Ratio
Factory InstalledFilter drier and liquid line solenoid valve
Control OptionsCompatible with standard thermostats
DimensionsCompact design for residential installation

Installation Requirements

Unpack and inspect unit for shipping damage. Select a suitable outdoor location.

  1. Location: Place on level concrete pad or approved mounting system with proper clearance.
  2. Clearances: Maintain minimum 24 inches from walls, shrubs, or obstructions for airflow.
  3. Electrical: Ensure proper voltage (208/230V) and dedicated circuit breaker.
  4. Refrigerant Lines: Connect pre-charged linesets following manufacturer guidelines.
  5. Condensate Drain: Install according to local codes.

WARNING! Unit is heavy; use proper lifting equipment. Installation must be performed by a qualified HVAC technician.

First-Time Setup

After installation, perform initial startup procedure.

  1. Electrical Check: Verify correct voltage and proper grounding.
  2. Refrigerant Charge: Check charge using superheat/subcooling method.
  3. Thermostat Wiring: Connect to compatible thermostat following wiring diagram.
  4. System Test: Power on unit and test cooling operation in stages.
  5. Airflow Verification: Check indoor airflow and adjust blower speed if needed.

CAUTION! Disconnect power before servicing. Follow all local electrical codes.

Specifications

Controls and Settings

Unit operates with compatible thermostat. No user-adjustable controls on outdoor unit.

Thermostat Settings: COOL, OFF, HEAT (if heat pump), FAN AUTO/ON. Temperature setpoint adjustment.

LED Status Light: Located on control board - Green (normal operation), Red (fault condition).

Service Test Mode: Jumper specific terminals on control board for diagnostic operation (technician only).

Electrical Wiring

Connect to dedicated circuit with proper disconnect within sight of unit.

  1. Disconnect all power before wiring.
  2. Run appropriate gauge wire (minimum 10 AWG) from disconnect to unit.
  3. Connect L1, L2, and ground to terminal block.
  4. Connect low-voltage thermostat wires to appropriate terminals.
  5. Install properly rated fuses or circuit breaker.

Tip: Refer to wiring diagram on unit panel for specific connections.

Operation Instructions

System operates automatically based on thermostat settings.

  1. Set thermostat to COOL mode.
  2. Set desired temperature below room temperature.
  3. Fan setting: AUTO (runs with compressor) or ON (continuous).
  4. System will cycle on/off to maintain set temperature.
  5. For seasonal shutdown: Turn thermostat to OFF position.

WARNING! Do not operate below 55°F outdoor temperature without low ambient kit.

Maintenance Schedule

Regular maintenance ensures optimal performance and longevity.

FrequencyTaskNotes
MonthlyCheck/clean air filter (indoor unit)Replace if dirty
SeasonalClean outdoor coilRemove debris, straighten fins
AnnuallyProfessional inspectionCheck refrigerant charge, electrical connections
AnnuallyClean condensate drainPrevent clogging
As neededClear area around unitMaintain 24" clearance

Safety Information

Follow all safety precautions during installation, operation, and maintenance.

CAUTION! Disconnect all power before servicing. Refrigerant under pressure - handle with care. Wear appropriate PPE. Unit contains rotating parts - keep hands clear during operation.

Warranty Information

American Standard provides limited warranties for parts and compressor. Register product within 60 days of installation for full warranty coverage. For warranty claims, contact authorized dealer or American Standard at 1-800-628-4400. Visit www.americanstandardair.com for complete warranty terms and conditions.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower supply, thermostat, breakerCheck power, thermostat settings, reset breaker
Poor coolingDirty filter, low refrigerant, airflowClean/replace filter, check charge, verify airflow
Unit cycles on/off frequentlyDirty coil, thermostat location, overchargeClean coil, relocate thermostat, check charge
Unusual noisesLoose parts, debris, fan issuesTighten components, clear debris, check fan
Ice on refrigerant linesLow airflow, low charge, filterCheck filter, airflow, refrigerant charge
Water leakageClogged drain line, improper slopeClear drain line, ensure proper slope

Reset: Turn power off for 5 minutes, then restart.

Service: For persistent issues, contact qualified HVAC technician. American Standard support: 1-800-628-4400