The American Standard 4A7V0048A1000B is a high-efficiency residential split-system air conditioner with a nominal cooling capacity of 4 tons (48,000 BTU/h), featuring R-410A refrigerant, a scroll compressor, corrosion-resistant coil, sound-reducing fan, and compatibility with variable-speed air handlers. Designed for quiet operation and energy savings, it includes diagnostic LEDs, low-voltage connections, and requires professional installation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Outdoor condenser unit with scroll compressor, aluminum coil, fan motor, control board with diagnostic LEDs, refrigerant service valves, low-voltage terminal block, and disconnect box.
| Feature | Description |
|---|---|
| Compressor Type | Scroll compressor for reliability and efficiency |
| Refrigerant | R-410A (environmentally friendly) |
| Cooling Capacity | 4 tons (48,000 BTU/h) |
| SEER Rating | Up to 18 SEER for energy savings |
| Sound Reduction | Quiet fan and compressor design |
| Corrosion Protection | Coated coil and galvanized steel cabinet |
| Diagnostic LEDs | Onboard LEDs for troubleshooting |
| Compatibility | Works with variable-speed air handlers |
| Low-Voltage Connections | 24V terminal block for thermostat control |
| Disconnect Requirement | Field-supplied electrical disconnect |
Unpack and inspect unit for damage. Ensure proper location and clearances.
WARNING! Installation must be performed by a qualified HVAC technician. High voltage present; disconnect power before servicing.
After installation, perform initial startup and system check.
CAUTION! Do not operate without proper refrigerant charge. Ensure electrical connections are tight.
Primary control via thermostat; unit has internal control board with dip switches and diagnostic LEDs.
Thermostat Settings: COOL, OFF, HEAT (if heat pump), FAN AUTO/ON, temperature setpoints.
Unit Control Board: Dip switches for optional settings (fan delay, etc.). Diagnostic LEDs: Green (power), Yellow (compressor on), Red (fault code).
Adjustments: Refrigerant charge (field adjustable), fan speed (at air handler), thermostat programming.
Low-voltage wiring (24V) between thermostat, air handler, and outdoor unit.
Tip: Use 18-gauge thermostat wire; check connections for tightness.
Cooling only operation (standard); heat pump version available for heating.
WARNING! Do not set thermostat below 60°F; may cause coil freezing. Allow unit to complete cycles.
Regular maintenance ensures efficiency and longevity. Perform annually or per schedule.
CAUTION! Disconnect power before any maintenance. Refrigerant handling requires EPA certification.
Keep unit clear of debris, vegetation, and snow. Clean coil annually.
CAUTION! Do not use harsh chemicals or pressure washers on coil fins. Keep electrical components dry.
UL listed; complies with U.S. safety standards. EPA refrigerant handling regulations apply. Manufactured by American Standard Heating & Air Conditioning, a division of Trane Technologies. For support, visit www.americanstandardair.com or contact 1-800-628-4516. Model 4A7V0048A1000B is designed for residential use in North America.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power loss, thermostat setting | Check breaker/disconnect; set thermostat to COOL below room temp. |
| Poor cooling | Dirty filter, low refrigerant | Replace filter; check charge (requires technician). |
| Loud noise | Debris in fan, loose parts | Turn off power; remove debris; tighten mounting. |
| Ice on coils | Low airflow, low charge | Check filter and blower; call for service. |
| Diagnostic LED flashing | Fault code | Refer to fault code chart in manual; reset power if safe. |
Reset: Turn thermostat OFF, disconnect power for 1 minute, restore power.
Service: 1-800-628-4516; www.americanstandardair.com