The American Standard HVAC 21 Series is a high-efficiency residential heating, ventilation, and air conditioning system designed for reliable year-round comfort. This manual covers the AccuComfort™ Platinum 21 Variable-Speed Air Conditioner and Heat Pump models, featuring up to 21 SEER efficiency, variable-speed compressor technology, sound reduction systems, compatibility with communicating thermostats, and durable construction. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Variable-speed compressor, Climatuff® compressor technology, Spine Fin™ coil, sound-reducing top, communicating control capability, durable cabinet.
| Feature | Description |
|---|---|
| Variable-Speed Compressor | Adjusts capacity for precise temperature control and efficiency |
| Climatuff Compressor | Proven reliability in extreme temperatures |
| Spine Fin Coil | Enhanced heat transfer and corrosion resistance |
| Sound Reduction System | Quiet operation with insulated cabinet and fan design |
| Communicating Capability | Works with American Standard AccuLink™ communicating thermostats |
| High SEER Rating | Up to 21 SEER for maximum energy efficiency |
| Durable Cabinet | Weather-resistant paint and galvanized steel construction |
| Refrigerant | Uses R-410A environmentally friendly refrigerant |
| Service Access | Easy-access panels for maintenance |
| Warranty | Limited lifetime compressor warranty (registered) |
Unpack and inspect unit for shipping damage. Ensure proper location and clearances.
WARNING! Installation must be performed by qualified HVAC technician. Electrical shock hazard exists. Follow all local codes and manufacturer instructions.
After installation, perform system commissioning and customer orientation.
CAUTION! Do not operate without proper refrigerant charge. Allow system to complete startup sequence before testing.
Primary control through compatible thermostat. Unit has diagnostic LED and service test mode.
Thermostat Options: AccuLink Comfort Control II (communicating), conventional 24V thermostats with proper interface.
System Settings: Cooling setpoint, heating setpoint, fan mode (auto/on), system mode (cool/heat/auto/off), fan speed (auto/variable), schedule programming, humidity control, filter reminder. Service Settings: Test mode (activated by service switch), compressor speed adjustment, fault code display, system monitoring.
Communicating thermostat: Uses 4-wire connection for full feature access. Conventional thermostat: May require interface module.
Tip: Use only American Standard approved thermostats for full functionality and warranty coverage.
Provides cooling, heating (heat pump models), fan-only, and auto changeover operation.
WARNING! Do not set thermostat to extreme temperatures. Allow system to complete cycles. Heat pump may not operate efficiently below certain outdoor temperatures.
Regular maintenance ensures optimal performance and longevity.
| Maintenance Item | Frequency | Procedure |
|---|---|---|
| Air Filter | Monthly/As needed | Check and clean/replace indoor air filter |
| Outdoor Coil | Seasonally | Clean debris from outdoor coil with water spray |
| Indoor Coil | Annually | Professional inspection and cleaning if needed |
| Condensate Drain | Seasonally | Check and clear drain line of obstructions |
| Electrical Connections | Annually | Professional inspection of all connections |
| Refrigerant Charge | As needed | Professional verification and adjustment |
Service: Contact qualified HVAC technician for annual maintenance and repairs.
Turn off power before cleaning. Keep outdoor unit clear of debris.
CAUTION! Do not use pressure washer on outdoor coil. Do not bend coil fins. Keep all electrical components dry.
UL listed and AHRI certified. Complies with U.S. Department of Energy efficiency standards. Contains refrigerant that must be recovered by certified technicians. Manufactured by American Standard Heating & Air Conditioning, a division of Ingersoll Rand. For support, visit www.americanstandardair.com or contact 1-800-628-4516. Register product online for full warranty benefits.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| System not running | Power loss, thermostat setting | Check disconnect switch and circuit breaker; verify thermostat settings. |
| Insufficient cooling/heating | Dirty filter, low refrigerant | Clean/replace filter; contact technician for refrigerant check. |
| Unusual noises | Loose parts, debris | Turn off system; check for loose panels or debris in fan; call for service. |
| Ice on coils | Dirty filter, low airflow | Turn system off; clean filter; allow ice to melt; call for service if persistent. |
| Error codes on thermostat | System fault | Note code; turn system off and on; if persists, call for service with code information. |
| Fan not running | Motor issue, capacitor | Turn off power; check for obstruction; call for service. |
Reset: Turn off at thermostat and disconnect for 5 minutes, then restart.
Service: 1-800-628-4516; www.americanstandardair.com